3.Troubleshooting
30
Code Meaning Suggested Cause/Action
6-10 G3 ECM - error frames still received at
the other end after all communication
attempts at 2400 bps
• Check for line noise.
• Adjust the tx level (use NCU parameter 01 or the
dedicated tx parameter for that address).
• Check the line connection.
• Defective remote terminal.
6-21 V.21 flag detected during high speed
modem communication
• The other terminal may be defective or incompatible.
6-22 The machine resets the sequence because
of an abnormal handshake in the V.34
control channel
• Check for line noise.
• If the same error occurs frequently, replace the FCU.
• Defective remote terminal.
6-99 V.21 signal not stopped within 6 s
• Replace the FCU.
9-30 HDD write error
• Check the connection of the HDD.
• If the problem persists, replace the HDD and/or
harness.
9-31 HDD control error
9-32 HDD read error
9-33 HDD fatal error
13-
17
SIP user name registration error
• Double registration of the SIP user name.
• Capacity for user-name registration in the SIP server
is not sufficient.
13-
18
SIP server access error
• Incorrect initial setting for the SIP server.
• Defective SIP server.
13-
24
SIP authentication error
• Registered password in the device does not match the
password in the SIP server.
13-
25
Network I/F setting error
• IPV4 is not active in the active protocol setting.
• IP address of the device is not registered.
13-
26
Network I/F setting error at power on
• Active protocol setting does not match the I/F setting
for SIP server.
• IP address of the device is not registered.
13-
27
IP address setting error
• IP address of the device is not registered.
14-
00
SMTP Send Error
• Error occurred during sending to the SMTP server.
Occurs for any error other than 14-01 to 16. For
example, the mail address of the system administrator
is not registered.
14-
01
SMTP Connection Failed
• Failed to connect to the SMTP server (timeout)
because the server could not be found.
• The PC is not ready to transfer files.
• SMTP server not functioning correctly.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh MP C307 and is the answer not in the manual?

Ricoh MP C307 Specifications

General IconGeneral
TypeMultifunction Printer
FunctionsPrint, Copy, Scan, Fax
Print TechnologyLaser
Print Resolution1200 x 1200 dpi
Maximum Paper SizeA4
Duplex PrintingYes
Scan Resolution600 x 600 dpi
Mobile PrintingApple AirPrint, Google Cloud Print, Mopria
Operating Systems SupportedWindows, Mac OS, Linux
Print Speed (Black)30 ppm
Print Speed (Color)30 ppm
Standard Paper Capacity350 sheets
Supported Paper SizesA4, A5, A6, B5, B6, Letter, Legal
Scanner TypeFlatbed with ADF (Automatic Document Feeder)
Copier Speed (Black)30 cpm
Copier Speed (Color)30 cpm
Copy ResolutionUp to 600 dpi
Zoom Range25% to 400%
ConnectivityEthernet, USB
Max. Paper Capacity1, 350 sheets
Display10.1-inch color touchscreen