4.Service Tables
59
1: Memory tx and rx
operation (the display
remains the same)
1: The display stays in standby mode even when the external handset is
used, so that other people can use the machine for memory tx operation.
Note that manual tx and rx are not possible with this setting.
4-
7
Not used Do not change these settings.
System Switch 0F (SP No. 1-101-016)
No Function Comments
0
to
7
Country/area code for
functional settings (Hex)
This country/area code determines the factory settings of bit switches and
RAM addresses. However, it has no effect on the NCU parameter
settings and communication parameter RAM addresses.
Cross reference
NCU country code:
SP No. 2-103-001 for G3-1
SP No. 2-104-001 for G3-2
SP No. 2-105-001 for G3-3
00: France 12: Asia
01:
Germany
13: Japan
02: UK 14: Hong
Kong
03: Italy 15: South
Africa
04: Austria 16: Australia
05: Belgium 17: New
Zealand
06:
Denmark
18: Singapore
07: Finland 19: Malaysia
08: Ireland 1A: China
09: Norway 1B: Taiwan
0A: Sweden 1C: Korea
0B: Switz. 1D: Brazil
0C:
Portugal
20: Turkey
0D: Holland 21: Greece
0E: Spain 22: Hungary
0F: Israel 23: Czech
10: --- 24: Poland
11: USA
System Switch 10 (SP No. 1-101-017)
No Function Comments
0-7 Threshold memory level for parallel memory transmission Threshold = N x 128 KB + 256 KB