Image Adjustment
198
4. Rotate the knob(s) shown in the diagram [A] to [D] at 90 degree intervals until the SP value for the
affected color(s) is within ±5 (target: 0).
• There are two knobs on each of the two LD units. A click is felt every 90 degree rotation.
• Turning the knob clockwise by 90 degrees changes the SP value by -1.
• Turning the knob counter-clockwise by 90 degrees changes the SP value by +1.
• Example:
SP value for magenta in Step 4 was “+6” Turn knob [C] 6 clicks (1 1/2 rotations) clockwise.
• SP value for yellow in Step 4 was “-7” Turn knob [D] 7 clicks (1 3/4 rotations)
counter-clockwise.
5. Reattach all parts that you removed in the above steps.
• Do not touch the LD units while installing the Paper Exit Tray. Otherwise, the LD unit may
move, and you may have to adjust the color skew again.