Firmware Update (Auto Remote Firmware Update)
376
3. Controller Board
4. Operation Panel
For example, when the update process is cancelled while updating the first module of the operation panel, the
machine will reboot when all modules in the operation panel have been updated.
The firmware contents included in the package can be referred to in the release note in the SERES release of the
package.
The next update will run 76 hours after the cancellation. The old (cancelled) package will be discarded if the
package downloaded 76 hours later is the latest.
Checking the ARFU Result
1. Enter the SP mode.
2. Press [Firmware update].
3. Press [Update].
4. Press [Update Package Information].
5. If the firmware package is the same as the one on the global server, the update was completed successfully.
Otherwise, check the result using the logging date.
In SP7-520-041 to -045 (Update Log: Auto:Version), you can check the versions of the packages updated
by ARFU. (-041 displays the latest result. It is also printed on the SMC sheet.)
Checking the Result Using the Logging Data
1. Enter the SP mode.
2. Press [System/Copy].
3. Check the results for ARFU by SP7-520-051 to 060 (Update Log: Auto:Result)
"-051" is the latest update result. For details about the number of each result log, see the next section
“Related SP.”
Related SP
SP Number Selection
Def.
Overview
SP5-886-111
0: OFF
1: ON
Sets auto update by ARFU ON/OFF .
SP5-886-112
0: OFF
1: ON
Will not run the update when update prohibited time setting is ON and the
current time is in the range of the time set.
• Start time < End time: Prohibited time is from the start time to the end time
on the same day.
•
Start time > End time: Prohibited time is from the start time to the end time
on the next day.
• Start time == End time: Prohibited time setting is disabled. (Update will
SP5-886-113 0 to 23
9
SP5-886-114 0 to 23
17