UP/SP Data Import/Export
403
If you cannot solve the problem or do not know how to solve it after checking the code, note down the error log
entry, then contact your supervisor.
Result Code Cause Solutions
2 (INVALID
REQUEST)
A file import was attempted between
different models or machines with different
device configurations.
Import files exported from the same model
with the same device configurations.
4 (INVALID
OUTPUT DIR)
Failed to write the device information to
the destination device.
Check whether the destination device is
operating normally.
7( MODULE
ERROR)
An unexpected error occurred during
import or export.
Switch the power off and then back on, and
then try the operation again. If the error
persists, contact your supervisor.
8 (DISK FULL) The available storage space on the external
medium is insufficient.
Execute the operation again after making sure
there is enough storage space.
9 (DEVICE
ERROR)
Failed to write or read the log file.
Check whether the path to the folder for storing
the file or the folder in which the file is stored
is missing.
10 (LOG
ERROR)
The hard disk is faulty. Contact your supervisor.
20 (PART
FAILED)
Failed to import some settings. The reason for the failure is logged in
"NgCode". Check the code.
Reason for the Error (Ng-Name)
2. INVALID VALUE
The specified value exceeds the allowable
range.
3. PERMISSION ERROR
The permission to edit the setting is missing.
4. NOT EXIST