SC3xx: Image Processing
429
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Replace the PCDU.
Replace the development motor (CMY).
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC325-01 D Development motor (CMY) error (When motor is deactivated)
The motor LOCK signal is not detected for more than 2 seconds while the motor START
signal is OFF.
Defective development motor (CMY)
Disconnected harness for the motor
Defective BiCU
Replace the development motor (CMY).
Replace the harness for the development motor (CMY).
Replace the BiCU.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC396-00 D Drum motor (K) error
SC397-00 D Drum motor (CMY) error
The
motor LOCK signal is detected for more than 2 seconds while the motor START signal is
ON.
PCDU overload
Drum motor (K) failure (SC396)
Drum motor (CMY) failure (SC397)
Replace the PCDU.
Replace the drum motor (K) (SC396)
Replace the drum motor (CMY) (SC397)
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC396-01 D Drum motor (K) error (When motor is deactivated)
SC397-01 D Drum motor (CMY) error (When motor is deactivated)
The motor LOCK signal is not detected for more than 2 seconds while the motor START
signal is OFF.
Drum motor (K) failure (SC396)
Drum motor (CMY) failure (SC397)
Disconnected harness for the drum motor
Defective BiCU
PCDU torque increased
Replace the drum motor (K) (SC396)