SC8xx: Overall System
467
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC820-00 C Self-diagnostics error: CPU
[XXXX]: Detailed error code
[0601] Read address exception error
[0602] Write address exception error
[0605] System call exception error
[0606] Break exception error
[0607] Invalid instruction exception error
[0609] Overflow exception error
Exception does not occur though executing exception by intention.
CPU device error
Replace the controller board
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC820-00 C Self-diagnostics error: CPU
[XXXX]: Detailed error code
[060A] Interrupt line 0 mask exception error
[060B] Interrupt line 1 mask exception error
[060C] Interrupt line 2 mask exception error
[060D] Interrupt line 3 mask exception error
[060E] Interrupt line 4 mask exception error
Interrupt does not occur though setting interrupt by timer.
• CPU device error
• ASIC device error
Replace the controller board.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC820-00 C Self-diagnostics error: CPU
[XXXX]: Detailed error code
[0610] CPU interrupt timer 2 set error
Interrupt does not occur though setting interrupt by CPU interrupt timer.
CPU device error
Replace the controller board
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC820-00 C Self-diagnostics error: CPU
[XXXX]: Detailed error code