SC8xx: Overall System
467
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC820-00 C Self-diagnostics error: CPU
[XXXX]: Detailed error code
[0601] Read address exception error
[0602] Write address exception error
[0605] System call exception error
[0606] Break exception error
[0607] Invalid instruction exception error
[0609] Overflow exception error
Exception does not occur though executing exception by intention.
CPU device error
Replace the controller board
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC820-00 C Self-diagnostics error: CPU
[XXXX]: Detailed error code
[060A] Interrupt line 0 mask exception error
[060B] Interrupt line 1 mask exception error
[060C] Interrupt line 2 mask exception error
[060D] Interrupt line 3 mask exception error
[060E] Interrupt line 4 mask exception error
Interrupt does not occur though setting interrupt by timer.
CPU device error
ASIC device error
Replace the controller board.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC820-00 C Self-diagnostics error: CPU
[XXXX]: Detailed error code
[0610] CPU interrupt timer 2 set error
Interrupt does not occur though setting interrupt by CPU interrupt timer.
CPU device error
Replace the controller board
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC820-00 C Self-diagnostics error: CPU
[XXXX]: Detailed error code

Table of Contents