SC8xx: Overall System
475
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
The loopback connector is connected but check results is an error.
ASIC device error
IEEE1284 connector error
Centronic loopback connector is defective
Replace the controller board.
[1120] Loopback connector not detected
Centronic loopback connector is not connected for detailed self-diagnostic test.
Centronic loopback connector not connected correctly
Centronic loopback connector is defective
ASIC device is defective
Connect the centronic loopback connector
Replace the centronic loopback connector
Replace the controller board.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC838-00 C Self-diagnostic Error: Clock Generator
[xxxx]: Detailed error code
[2701] Verify error
A verify error occurred when setting data was read from the clock generator via the I2C bus.
Defective clock generator
Defective I2C bus
Defective I2C port on the CPU
Replace the controller board.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC839-00 D Self-diagnostic Error: Serial Flash
[xxxx]: Detailed error code
[9001] Serial Flash access error
USB NAND Flash ROM cannot be read.
Defective controller board
Replace the controller board.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC840-00 D EEPROM access error
During the I/O processing, a reading error occurred. The 3rd reading failure causes this
SC code.
During the I/O processing, a writing error occurred.