SC8xx: Overall System
492
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC878-20 D Random number test error
An error was detected when a random number table was generated during a self-test.
TPM is defective
Turn the main power OFF/ON.
Replace the controller board if the SC occurs again.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC878-21 D DESS self-test error
The power-on self-
test for TPM failed at startup when the controller encryption software was
tested.
TPM firmware or CPU is defective
Turn the main power OFF/ON.
Replace the controller board.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC880-00 D MLB error
Reply to MLB access was not returned within a specified time.
MLB defective
Replace the MLB.
Remove the MLB.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC881-01 D Management area error
A problem was detected in the software
This error may even occur is an IC card option is not installed.
This is caused by accumulation of abnormal authentication information in the software.
(User operation will not directly cause it.)
At login
Example: When a job is sent to the printer/when logged on from the operation
panel/when logged on from a Web browser
Cycle the main power off and on.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC899-00 D Software performance error (signal reception end)
Unknown software error occurred.
Occurs when an internal program behaves abnormally.
In the case of a hardware defect