3.SP Mode Tables
131
004 Edge
2-636-
007
Special 4: SW Timing Lead
Edge
Separation DC: 1Side ENG* [ 0 to 50 / 0 / 2mm ]
2-636-
008
Special 4: SW Timing Lead
Edge
Separation DC: 2Side ENG* [ 0 to 50 / 0 / 2mm ]
2-637-
003
Special 4:
TrailEdgeCorrection
Paper Transfer: 1Side ENG* [ 0 to 995 / 100 / 5% ]
2-637-
004
Special 4:
TrailEdgeCorrection
Paper Transfer: 2Side ENG* [ 0 to 995 / 100 / 5% ]
2-637-
007
Special 4:
TrailEdgeCorrection
Separation DC: 1Side ENG* [ 0 to 995 / 100 / 5% ]
2-637-
008
Special 4:
TrailEdgeCorrection
Separation DC: 2Side ENG* [ 0 to 995 / 100 / 5% ]
2-638-
003
Special 4: SWTiming Trail
Edge
Paper Transfer: 1Side ENG* [ 0 to 50 / 0 / 2mm ]
2-638-
004
Special 4: SWTiming Trail
Edge
Paper Transfer: 2Side ENG* [ 0 to 50 / 0 / 2mm ]
2-638-
007
Special 4: SWTiming Trail
Edge
Separation DC: 1Side ENG* [ 0 to 50 / 0 / 2mm ]
2-638-
008
Special 4: SWTiming Trail
Edge
Separation DC: 2Side ENG* [ 0 to 50 / 0 / 2mm ]
2-639-
015
Special 4: EnvCorrectionTable Separation DC: 1Side ENG* [ 1 to 100 / 30 / 1 ]
2-639-
016
Special 4: EnvCorrectionTable Separation DC: 2Side ENG* [ 1 to 100 / 30 / 1 ]
2-639-
019
Special 4: Edge Envir Correc. Separation DC: 1Side ENG* [ 1 to 100 / 30 / 1 ]
2-639-
020
Special 4: Edge Envir Correc. Separation DC: 2Side ENG* [ 1 to 100 / 30 / 1 ]
2-641-
003
Special 5: Bias Separation DC: 1Side ENG* [ 0 to 4000 / 2000 /
10-V ]
2-641-
004
Special 5: Bias Separation DC: 2Side ENG* [ 0 to 4000 / 2000 /
10-V ]
2-643-
003
Special 5: Bias: BW Paper Transfer: 1Side ENG* [ 0 to 200 / 11 / 1uA ]
2-643-
004
Special 5: Bias: BW Paper Transfer: 2Side ENG* [ 0 to 200 / 8 / 1uA ]
2-647- Special 5: Bias: FC Paper Transfer: 1Side ENG* [ 0 to 200 / 12 / 1uA ]