1232-28: Fusing Temperature: S: Heat Roller Temp: Metallic
High Quality
1232-46: Fusing Temperature: BW/FC/FCS: Fuser Setting HQ: Heat Roller Temp
1232-51: Fusing Temperature: FCS: Fuser Setting HQ: Heat Roller Temp: Clear/Special
1232-52: Fusing Temperature: FCS: Fuser Setting HQ: Heat Roller Temp: White
1232-53: Fusing Temperature: FCS: Fuser Setting HQ: Heat Roller Temp: Metallic
1232-71: Fusing Temperature: S: Fuser Setting HQ: Heat Roller Temp: Clear/Special
1232-72: Fusing Temperature: S: Fuser Setting HQ: Heat Roller Temp: White
1232-73: Fusing Temperature: S: Fuser Setting HQ: Heat Roller Temp: Metallic
11. Set the value in the following corresponding settings to 0°C.
Productivity Priority
1232-02: Fusing Temperature: BW/FC/FCS: Correct Temp: Initial Feed
1232-10: Fusing Temperature: FCS: Correct Temp: Initial Feed: Clear/Special
1232-11: Fusing Temperature: FCS: Correct Temp: Initial Feed: White
1232-12: Fusing Temperature: FCS: Correct Temp: Initial Feed: Metallic
1232-30: Fusing Temperature: S: Correct Temp: Initial Feed: Clear/Special
1232-31: Fusing Temperature: S: Correct Temp: Initial Feed: White
1232-32: Fusing Temperature: S: Correct Temp: Initial Feed: Metallic
High Quality
1232-47: Fusing Temperature: BW/FC/FCS: Fuser Setting HQ: Correct Temp: Initial Feed
1232-55: Fusing Temperature: FCS: Fuser Setting HQ: Correct Temp: Initial Feed: Clear/
Special
1232-56: Fusing Temperature: FCS: Fuser Setting HQ: Correct Temp: Initial Feed: White
1232-57: Fusing Temperature: FCS: Fuser Setting HQ: Correct Temp: Initial Feed: Metallic
1232-75: Fusing Temperature: S: Fuser Setting HQ: Correct Temp: Initial Feed: Clear/Special
1232-76: Fusing Temperature: S: Fuser Setting HQ: Correct Temp: Initial Feed: White
1232-77: Fusing Temperature: S: Fuser Setting HQ: Correct Temp: Initial Feed: Metallic
12. Set the value in the following corresponding settings to 5°C.
Productivity Priority
1232-03: Fusing Temperature: BW/FC/FCS: Correct Temp: Pre-Feed
1232-14: Fusing Temperature: FCS: Correct Temp: Pre-Feed: Clear/Special
1232-15: Fusing Temperature: FCS: Correct Temp: Pre-Feed: White
1232-16: Fusing Temperature: FCS: Correct Temp: Pre-Feed: Metallic
4. Image Quality Problem: Full Page