2 Command System RIGOL
DS2000E Programming Guide
:TRIGger:VIDeo:LEVel
Syntax
:TRIGger:VIDeo:LEVel <level>
:TRIGger:VIDeo:LEVel?
Description
Set or query the trigger level of video trigger. The unit is the same with the current amplitude unit.
Parameter
Name Type Range Default
<level> Real (-5 x VerticalScale - OFFSet) to (+5 x VerticalScale - OFFSet) 0
Note: For the VerticalScale, refer to the :CHANnel<n>:SCALe command. For the OFFSet, refer to
the
:CHANnel<n>:OFFSet command.
Return Format
The query returns the trigger level of video trigger in scientific notation.