1. OUTLINE
IMR02C15-E4
1-3
1.2 Input/Output and Function Blocks
This section describes the input/output and function blocks of the instrument.
Communication function is not
available with DI1 and DI2 on
RB100.
Control processing
• PID control
• Heat/Cool PID control
• ON/OFF control
• Autotuning (AT)
• Startup tuning (ST)
• Fine tuning
• Direct/Reverse action
• Output limiter
Communication
processing
Input processing
• PV digital filter
• PV bias
Current capture
processing
DI function assignment
• SV selection
• RUN/STOP transfer
• AUTO/MAN transfer
• Interlock release
PV monitor
Current value
monitor
RTD
CT1 *
DI2 *
Transmission output
(Voltage/Current)*
• Measured value (PV)
• Set value (SV)
• Manipulated output
value (MV1)
TC
Voltage/Current
SV1
SV2
SV3
SV4
Setting change rate limiter
SV monitor
Timer function
• Timer 1 to 4
• Timer time
• Timer function
• Repeat execution times
COM-K must be used to connect to
a PC via the loader port.
RS-485
Communication
f
u
n
c
ti
o
n *
Loader
communication
RKC
communication
MV monitor
Control output
(heat-side)
Control output
(cool-side)
OUT1
OUT2
OUT2 can be used as
Event 3 output for RB100.
DO1
DO2
DO3
DO4
DO3 and DO4 are not
available with RB100.
DI1 and DI2 are not available
with Communication function
on RB100.
Delay timer
Interlock
Energized/De-energized
Event 1 to 4 processing
• Temperature alarm
• Heater break alarm
(HBA)
• Control loop break alarm
(LBA)
• Monitor during RUN
• Communication monitoring
• FAIL
FAIL output [fixed at
de-energized]
(contact open when
error occurs)
CT2 *
Measured
input
CT input
Control output
• Relay contact
• Voltage pulse
• Voltage/Current
• Triac
• Open collector
Event output
• Relay contact
Manual manipulated
output value
Output
limiter
Output
limiter
A
UTO
MAN
Output types and
functions vary
based on the model
code.
DI1 *
: Monitor display
Marked
*: Optional
Set value
Remaining time monitor
SV selection
(Front key, DI,
communication)
RUN/STOP transfe
r
(Front key, DI,
communication)
Auto (AUTO)/Manual (MAN) transfer
(Front key, DI, communication)
Interlock release
(Front key, DI,
communication
)
Digital input
• Dry contact
Event 1
Event 2
Event 3
Event 4
Protocol selections
(Ramp/Soak control)
Modbus
FAIL output

Table of Contents

Other manuals for RKC INSTRUMENT RB Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RKC INSTRUMENT RB Series and is the answer not in the manual?

RKC INSTRUMENT RB Series Specifications

General IconGeneral
BrandRKC INSTRUMENT
ModelRB Series
CategoryTemperature Controller
LanguageEnglish

Related product manuals