INDEX
IMR02C15-E4 B-3
Character Order
Symbol Name Mode * Page
A (
A
)
Add
Add Device Address ENG (F60) 8-133
AHS
AHS Transmission output scale high ENG (F33) 8-99
ALS
ALS Transmission output scale low ENG (F33) 8-99
Ao
Ao Transmission output type ENG (F33) 8-98
AoFS
AoFS AO full scale adjustment value ENG (F33) 8-100
AoZR
AoZR AO zero adjustment value ENG (F33) 8-100
ARW
ARW Anti-reset windup (ARW)
PARA,
ENG
(F06)
8-27,
8-74
ATC
ATC AT cycles ENG (F52) 8-130
ATH
ATH AT differential gap time ENG (F52) 8-131
ATU
ATU Autotuning (AT)
PARA,
ENG
(F05)
8-24,
8-71
AUTo
AUTo
Auto (AUTO)/Manual (MAN)
transfer [Auto (AUTO) mode]
MODE 8-10
B (b) (
b
)
bIT
bIT Data bit configuration ENG (F60) 8-134
boS
boS Burnout direction ENG (F21) 8-90
bPS
bPS Communication speed ENG (F60) 8-134
bUMP
bUMP Bumpless mode setting ENG (F51) 8-127
C (
C
)
CMPS
CMPS Communication protocol ENG (F60) 8-133
CMRM
CMRM Communication response monitor ENG (F60) 8-135
CT1
CT1
Current transformer 1 (CT1) input
value monitor
MONI 8-4
CT2
CT2
Current transformer 2 (CT2) input
value monitor
MONI 8-4
CTR
CTR CT ratio (Number of turns) ENG (F45) 8-122
D (d) (
d
)
d
d Derivative time
PARA,
ENG
(F06)
8-27,
8-74
db
db Overlap/Deadband
PARA,
ENG
(F06)
8-29,
8-75
dF
dF PV digital filter
PARA,
ENG
(F09)
8-41,
8-84
dISL
dISL DI assignment ENG (F23) 8-95
dSoP
dSoP PV flashing display at input error ENG (F21) 8-94
dTP
dTP Derivative action ENG (F51) 8-128
E (
E
)
Ebo1
Ebo1
Event 1 output action at input
burnout
ENG (F41) 8-115
Ebo2
Ebo2
Event 2 output action at input
burnout
ENG (F42) 8-115
Ebo3
Ebo3
Event 3 output action at input
burnout
ENG (F43) 8-115
Ebo4
Ebo4
Event 4 output action at input
burnout
ENG (F44) 8-115
EH1
EH1 Event 1 differential gap ENG (F41) 8-113
EH2
EH2 Event 2 differential gap ENG (F42) 8-113
EH3
EH3 Event 3 differential gap ENG (F43) 8-113
EH4
EH4 Event 4 differential gap ENG (F44) 8-113
EHo1
EHo1 Event 1 hold action ENG (F41) 8-110
EHo2
EHo2 Event 2 hold action ENG (F42) 8-110
EHo3
EHo3 Event 3 hold action ENG (F43) 8-110
EHo4
EHo4 Event 4 hold action ENG (F44) 8-110
EIL1
EIL1 Event 1 interlock ENG (F41) 8-120
EIL2
EIL2 Event 2 interlock ENG (F42) 8-120
EIL3
EIL3 Event 3 interlock ENG (F43) 8-120
EIL4
EIL4 Event 4 interlock ENG (F44) 8-120
Symbol Name Mode * Page
ES1
ES1 Event 1 type ENG (F41) 8-101
ES2
ES2 Event 2 type ENG (F42) 8-101
ES3
ES3 Event 3 type ENG (F43) 8-101
ES4
ES4 Event 4 type ENG (F44) 8-101
EV1
EV1
Event 1 set value (EV1)
Event 1 set value (EV1) [high]
PARA,
ENG
(F04)
8-20,
8-68
EV1`
EV1' Event 1 set value (EV1') [low]
PARA,
ENG
(F04)
8-22,
8-69
EV2
EV2
Event 2 set value (EV2)
Event 2 set value (EV2) [high]
PARA,
ENG
(F04)
8-20,
8-68
EV2`
EV2' Event 2 set value (EV2') [low]
PARA,
ENG
(F04)
8-22,
8-69
EV3
EV3
Event 3 set value (EV3)
Event 3 set value (EV3) [high]
PARA,
ENG
(F04)
8-20,
8-68
EV3`
EV3' Event 3 set value (EV3') [low]
PARA,
ENG
(F04)
8-22,
8-69
EV4
EV4
Event 4 set value (EV4)
Event 4 set value (EV4) [high]
PARA,
ENG
(F04)
8-20,
8-68
EV4`
EV4' Event 4 set value (EV4') [low]
PARA,
ENG
(F04)
8-22,
8-69
EVT1
EVT1 Event 1 timer ENG (F41) 8-118
EVT2
EVT2 Event 2 timer ENG (F42) 8-118
EVT3
EVT3 Event 3 timer ENG (F43) 8-118
EVT4
EVT4 Event 4 timer ENG (F44) 8-118
EXC1
EXC1
Energized/De-energized of Event 1
output
ENG (F41) 8-116
EXC2
EXC2
Energized/De-energized of Event 2
output
ENG (F42) 8-116
EXC3
EXC3
Energized/De-energized of Event 3
output
ENG (F43) 8-116
EXC4
EXC4
Energized/De-energized of Event 4
output
ENG (F44) 8-116
H (
H
)
HbA1
HbA1
Heater break alarm 1 (HBA1) set
value
PARA,
ENG
(F07)
8-31,
8-77
HbA2
HbA2
Heater break alarm 2 (HBA2) set
value
PARA,
ENG
(F07)
8-31,
8-77
HbC
HbC Number of HBA delay times ENG (F45) 8-123
I (
I
)
I
I Integral time
PARA,
ENG
(F06)
8-26,
8-73
ILR
ILR Interlock release MODE 8-11
INP
INP Input type ENG (F21) 8-88
INT
INT Interval time ENG (F60) 8-135
L (
L
)
LbA
LbA
Control loop break alarm (LBA)
time
PARA,
ENG
(F07)
8-32,
8-78
Lbd
Lbd LBA deadband (LBD)
PARA,
ENG
(F07)
8-34,
8-78
LCK
LCK Set data unlock/lock transfer [Lock] MODE 8-10
LocK
LocK Set lock level ENG (F00) 8-57
M (
M
)
MAN
MAN
Auto (AUTO)/Manual (MAN)
transfer [Manual (MAN) mode]
MODE 8-10
M-MV
M-MV
Manual manipulated output value
(MV)
PARA,
ENG
(F10)
8-42,
8-86
ModE
ModE Mode selection (no display) ENG (F00) 8-58
MoNI
MoNI Monitor selection (no display) ENG (F00) 8-58
MT
MT
Minimum ON/OFF time of
proportioning cycle [heat-side]
PARA,
ENG
(F08)
8-37,
8-80
Mt
Mt
Minimum ON/OFF time of
proportioning cycle [cool-side]
PARA,
ENG
(F08)
8-40,
8-82
MV
MV
Manipulated output value (MV1)
monitor [heat-side]
MONI 8-4
MV2
MV2
Manipulated output value (MV2)
monitor [cool-side]
MONI 8-5
* Mode
MONI: Monitor display Mode MODE: Mode switching
PARA: Parameter Setting mode ENG: Engineering mode