Remote Control Commands
R&S
®
RTB2000
285User Manual 1333.1611.02 ─ 04
15.6.4.3 Width Search Configuration
SEARch:TRIGger:WIDTh:POLarity.................................................................................. 285
SEARch:TRIGger:WIDTh:LEVel...................................................................................... 285
SEARch:TRIGger:WIDTh:LEVel:DELTa........................................................................... 285
SEARch:TRIGger:WIDTh:RANGe....................................................................................285
SEARch:TRIGger:WIDTh:WIDTh.....................................................................................286
SEARch:TRIGger:WIDTh:DELTa.....................................................................................286
SEARch:TRIGger:WIDTh:POLarity <Polarity>
Indicates the polarity of the pulse to be searched for.
Parameters:
<Polarity> POSitive | NEGative
*RST: POS
Example: Chapter 15.2.3.1, "Searching for a Pulse of Specified Width",
on page 246
SEARch:TRIGger:WIDTh:LEVel <Level>
Sets the voltage level on which the pulse width is measured.
Parameters:
<Level> *RST: 500 mV
SEARch:TRIGger:WIDTh:LEVel:DELTa <DeltaLevel>
Sets a hysteresis range above and below the search level to avoid unwanted search
results caused by noise oscillation around the level.
Parameters:
<DeltaLevel> Range: Lower limit depends on vertical scale and other set-
tings, no upper limit
*RST: 200 mV
SEARch:TRIGger:WIDTh:RANGe <Range>
Sets how the measured pulse width is compared with the given limit(s).
To set the width, use SEARch:TRIGger:WIDTh:WIDTh.
To set the range ± Δt, use SEARch:TRIGger:WIDTh:DELTa.