Remote Control Commands
R&S
®
RTB2000
309User Manual 1333.1611.02 ─ 04
Width of positive or negative pulses.
CYCMean
Mean voltage value of the left-most signal period of the wave-
form of the selected channel.
CYCRms
RMS (root mean square) voltage value of the left-most signal
period of the waveform of the selected channel.
STDDev
Standard deviation of the waveform.
CYCStddev
Standard deviation of one cycle, usually of the first, left-most sig-
nal period.
DELay
Time difference between two edges of the same or different
waveforms. The waveforms are selected with
MEASurement<m>:SOURce, and the edges with
MEASurement<m>:DELay:SLOPe.
PHASe
Phase difference between two waveforms (time difference/
period * 360). The waveforms are selected with
MEASurement<m>:SOURce.
BWIDth
Burst width, the duration of one burst, measured from the first
edge to the last edge that crosses the middle reference level.
POVershoot | NOVershoot
Positive and negative overshoot of a square wave.
*RST:
PEAK
MEASurement<m>:SOURce <SignalSource>[,<SignalSource2>]
Selects one of the active signal, reference or math channels as the source(s) of the
selected measurement. Available sources depend on the selected measurement type.
Suffix:
<m>
.
1..4
Selects the measurement place.