Functions and settings | 8
VERSION 1 | EN-US CIRUS
®
UPT-6400 Page 35 of 104
Menu
num-
ber
Menu
item
Available
only
when the
timer is
activated
(menu
number
401)
Description Setting range
107 AUTO-
CAL
This function adjusts the temperature controller to the
current and voltage signals present in the system.
Press Up and Down to set the desired calibration temper-
ature. Apply the set value and start AUTOCAL by press-
ing Enter.
During AUTOCAL, the message "Calibration" appears on
the screen and a timer counts down from 15 to 0. When
calibration has been completed successfully, the display
goes directly to the standard screen
If calibration cannot be performed, AUTOCAL is canceled
and a corresponding error code appears on the screen.
Start AUTOCAL by briefly (< 2 sec) pressing Enter.
Start MASTER-AUTOCAL by pressing Enter for longer
than 2 sec.
Refer to section Automatic zero calibration AUTOCAL
(AC) for further information.
0 … 40°C
110 Correc-
tion fac-
tor
The correction factor is used to adjust the temperature
controller to suit the actual properties of the machine.
Refer to section Correction factor [}79] for further infor-
mation.
25%...200%
111 Counter In this menu number, press Enter to reset the counter
shown in the standard screen to zero.
112 Load
recipe
This menu item specifies the current values of the se-
lected recipe. The loaded values also remain valid when
the temperature controller is switched off and then back
on.
115 Temper-
ature of
release
pulse
Set the temperature of the release pulse.
Refer to section Release pulse for further information.
Available only when Internal or External has been
selected in menu number 422.
0°C, 40°C … maxi-
mum temperature
(menu number 306)
116 Release
pulse de-
lay
Set the delay of the release pulse.
Refer to section Release pulse for further information.
Available only when Internal or External has been
selected in menu number 422.
0.00…9.98sec
117 Duration
of re-
lease
pulse
Set the duration of the release pulse.
Refer to section Release pulse for further information.
Available only when Internal or External has been
selected in menu number 422.
0.00…5.00sec