200
AL61 Parameter group range excess
Parameter group request exceeds
A~F range.
Check the communication
command whether is correct or not.
Execute any one instruction below
1. Power off the drive.
2. Press “SET” key at the alarm
message screen.
3. Activate the RES signal.
AL62 Parameter number range excess
Parameter group number request
exceeds the specific range.
Check the communication
command whether is correct or not.
Execute any one instruction below
1. Power off the drive.
2. Press “SET” key at the alarm
message screen.
3. Activate the RES signal.
AL63 Pr mode parameter range excess
Parameter command request
exceeds the specific range.
Check the communication
command whether is correct or not.
Execute any one instruction below
1. Power off the drive.
2. Press “SET” key at the alarm
message screen.
3. Activate the RES signal.
AL64 Pr mode parameters write error
To write parameter modification
when SON is activated.
Check the SON status when Pr command is going to be changed.