57
4.8. Parameter display
Some parameter modification would be valid by power off once and power on again.
(1) Decimal parameter (positive number)
Example: PA19 is 1234567, then to change to 1434567.
Press “SET” once.
The lower 5 digits of PA19 are shown and the lowest decimal point
indicates that this is low screen.
Press “MODE” once
The higher 2 digits of PA19 are shown and the second decimal point
indicates that this is high screen.
Press “MODE” once
The screen is returned to the low screen.
Press “SET” once
The lowest digit display would be flickering.
Press “MODE” for 5 times.
The flickering digit would shift left to the second high digit.
Press “UP” twice.
The flickering digit would be changed to “4”.
Press “SET” once to store the modification.