13
3. Wiring and signals
Any person who wires should be fully capable to do the work.
Before wiring, turn off the power and wait until the charge LED turns off.
Then, confirm that the voltage between +P and -N is safe with a voltage
meter. Otherwise, an electric shock may occur. In addition, when
confirming the charge LED, always check it from the front of the servo
drive.
Make the ground of the servo drive and motor securely.
Not to wire the servo drive and motor until they have been fixed.
Otherwise, it may cause an electric shock.
Be sure that the cable is completed, there is no any damaged.
Otherwise, it may cause an electric shock.
To avoid an electric shock, insulate the contacts of the power supply.
Wire the drive correctly and securely. Otherwise, the servo motor
may run unexpectedly, resulting in injury.
Connect cables to the correct terminals. Otherwise, a burst, damage,
etc. may occur.
The surge absorbing diode installed for the DC relay should be fitted
in the specified direction. Otherwise, the emergency stop and other
protective circuits may not work.
Do not modify the servo drive.
Connect the servo drive power output (U, V, W) to the servo motor
power input (U, V, W) directly. Do not let a magnetic contactor
intervene. Otherwise, it may cause a malfunction.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SDE-100A2 and is the answer not in the manual?

Shihlin electric SDE-100A2 Specifications

General IconGeneral
BrandShihlin electric
ModelSDE-100A2
CategoryDC Drives
LanguageEnglish

Related product manuals