10. Specifications
10.1. Drive specifications
3φ or 1φ 200~240Vac, 50/60Hz (3kW drive is suitable for only 3φ power)
3φ or 1φ 170~264Vac (3kW drive is suitable for only 3φ power)
Allowable
frequency Range
Allowable
frequency Range
3φ full-wave rectification, IGBT-PWM control (SVPWM)
Over current, over voltage, overload, fan failure protection, output short-circuit
protection, abnormal encoder protection, abnormal regeneration protection, low
voltage/power interruption protection, over speed protection, error excessive
2
22
(4,194,304) pulses/rev, maximum 65536 revolutions
RS485(ModBus protocol) ; USB
Line driver : 500Kpps(low)/4Mpps(high) ; Open collector : 200Kpps
CCW pulse + CW pulse ; Pulse + Direction ; A phase + B phase
External pulse train input/Inner register
Low-pass filter/Linear acceleration and deceleration pattern/S-pattern smoothing
Electronic gear ratio A/B-time, A: 1~4194304; B:1~4194304
1/50 < A/B < 64000
Parameter limit or torque analog limit (0~+10Vdc/Maximum torque)
Parameter setting: 0~200%