80
Communication related parameters
NO
Abbr.
Name
Default
Unit
Control mode
Pt
Pr
S
T
PC20()
SNO
Communication device number
1
-
PC21()
CMS
Communication mode option
0010h
-
PC22()
BPS
Communication protocol option
0010h
-
PC23
SIC
Communication time-out process option
0
S
Monitor and status display related parameters
NO
Abbr.
Name
Default
Unit
Control mode
Pt
Pr
S
T
PC14
MOD
Analog monitor output
0100h
-
PC24()
DMD
Status display option
0000h
-
PC28
MO1
Analog monitor ch1 offset
0
mV
PC29
MO2
Analog monitor ch2 offset
0
mV
PC30
MOG1
Analog monitor ch1 output proportion
100
%
PC31
MOG2
Analog monitor ch2 output proportion
100
%
Other functions related parameters
NO
Abbr.
Name
Default
Unit
Control mode
Pt
Pr
S
T
PA40(▲)
SPW
Special parameter write-enable
0000h
-
PA42()
BLK
Parameter write-inhibit
0000h
-
PB06
GD1
Load to motor inertia ratio
10
0.1time
PB14
GD2
The ratio 2 of load inertia to motor shaft
70
0.1time
PC18()
COP1
Stop option and power interruption restart option
0010h
-
PC19()
COP2
Alarm history clear option
0000h
-
PC36
BRP
Built-in brake resistor protection
300
ms
PC37()
MCS
Memory write-in protection
0
-
PD20()
DOP4
Alarm reset triggered process
0000h
-

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SDE-100A2 and is the answer not in the manual?

Shihlin electric SDE-100A2 Specifications

General IconGeneral
BrandShihlin electric
ModelSDE-100A2
CategoryDC Drives
LanguageEnglish

Related product manuals