Section 8: Wire and Cable Routing • May 2, 2016
© Copyright 2016 ShopBot Tools, Inc. page 8-7
Route Spindle Cable
Route orange spindle cable from the VFD, under the table, through the X-axis
e-chain, through the Y-axis e-chain, and into the spindle.
Keep spindle cable separate from the others, as it is capable of generating
noise, which could affect the machine electronics.
Close all e-chain gates.
Route cables under table to control box. If installing (or planning to install) 10”
table extension, ensure an extra 10” of slack is available in the cables.
Cable Checklist
Note: In both cable carriers, keep the spindle/router power cord separate from the other cables. This
will prevent electrical interference that may cause connection problems during use.
All wires and cables from the gantry will be carried in the X and Y axis cable carriers. Use this checklist
to inspect cables before closing the cable carrier.
Y Cable Carrier
_____ Spindle or router power cord
_____ Spindle fan cable (if applicable)
_____ Y motor cable
_____ Z motor cable
_____ Y-axis proximity switch
_____ Z-axis proximity switch (optional, stock for ATC tools only)
_____ Z zero plate and auxiliary function wire
Through Center of Gantry Beam
_____ X2 motor cable (route through the hole in the center of the gantry beam)
_____ Emergency stop switch (if mounted in predrilled location on end plate near X2 motor)
X Cable Carrier: All of the above, plus
_____ X1 motor cable (routed above the upper X cable carrier bracket)
_____ X-axis proximity switch
_____ Pneumatic air hoses (for ATC tools and optional air drills or pneumatic assists)