ONLINE HELP SOPAS Chapter 5
LECTOR®620
Parameters
8013778/Y269/2013-11-27 © SICK AG · Germany · All rights reserved · Subject to change without notice 89
DN - Device number Device number alternatively parameteruzed in
field bus; default: number is identical to "Device
ID"
DIN - Increment read from device Increment read by device
SID - Symbol ID Symbol ID
More obj. related items… Description
FIX1 - Fix defined string 1 User defined string 1
FIX2 - Fix defined string 2 User defined string 2
FIX3 - Fix defined string 3 User defined string 3
TT - Reading gate duration in ms Reading gate duration in ms
OTL - Trigger length in mm Trigger length in mm
NZ - Nr. of mismatches Number of mismatches (codes which do not fulfil
the matchcode condition)
NY - Nr. of no matches Number of objects without any match
GNC - Global nr. of codes Number of codes
NVRB - Global nr. valid released codes Number of valid released codes
NC - Number of reading gates Number of reading gates
DID - Device ID Device ID
SCGR - Superordinate counter Good Read Superordinate Good Read counter; remains in
case of a new parameterization (reset via power
cycle)
SCNR - Superordinate counter No Read Superordinate No Read counter; remains in case
of a new parameterization (reset via power cycle)
DEVN - Device name Device name
APC01 - Application counter 1 Definable counter 1
APC02 - Application counter 2 Definable counter 2
APC03 - Application counter 3 Definable counter 3
APC04 - Application counter 4 Definable counter 4
APC05 - Application counter 5 Definable counter 5
APC06 - Application counter 6 Definable counter 6
APC07 - Application counter 7 Definable counter 7
APC08 - Application counter 8 Definable counter 8
APC09 - Application counter 9 Definable counter 9
APC10 - Application counter 10 Definable counter 10
TS - Time stamp Time stamp of reading gate (start reading gate)
RR - Read rate Ration between Good Reads (SCGR) and num-
ber of reading gates
OGA - Distance between two objects Object to previous object in mm
Match counter… Description
Match1 Counter how often condition Match1 was ful-
filled (object related)
TeachIn1 Counter how often condition TeachIn1 was ful-
filled (object related)
TeachIn2 Counter how often condition TeachIn2 was ful-
filled (object related)
More… Description

Table of Contents

Other manuals for SICK Lector 620

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK Lector 620 and is the answer not in the manual?

SICK Lector 620 Specifications

General IconGeneral
BrandSICK
ModelLector 620
CategoryCard Reader
LanguageEnglish