ONLINE HELP SOPAS Chapter 5
LECTOR®620
Parameters
8013778/Y269/2013-11-27 © SICK AG · Germany · All rights reserved · Subject to change without notice 95
APC09 - Application counter 9 Definable counter 9
APC10 - Application counter 10 Definable counter 10
TS - Time stamp Time stamp of reading gate (start reading gate)
RR - Read rate Ration between Good Reads (SCGR) and num-
ber of reading gates
OGA - Distance between two objects Object to previous object in mm
Match counter… Description
Match1 Counter how often condition Match1 was ful-
filled (object related)
TeachIn1 Counter how often condition TeachIn1 was ful-
filled (object related)
TeachIn2 Counter how often condition TeachIn2 was ful-
filled (object related)
Superordinate counter…. Description
Match1 Counter how often condition Match1 was ful-
filled
TeachIn1 Counter how often condition TeachIn1 was ful-
filled
TeachIn2 Counter how often condition TeachIn2 was ful-
filled
Special character… Description
NUL 00H Null
SOH 01H Start of heading
STX 02H Start of text
ETX 03H End of text
EOT 04H End of transmission
ENQ 05H Enquiry
ACK 06H Acknowledge
BEL 07H Bell
BS 08H Backspace
HT 09H Horizontal tab
LF 0AH NL line feed, new line
VT 0BH Verticval tab
FF 0CH NP from feed, new page
CR 0DH Carriage return
SO 0EH Shift out
SI 0FH Shift in
DLE 10H Data link escape
DC1 11H Device control 1
DC2 12H Device control 2
DC3 13H Device control 3
DC4 14H Device control 4
NAK 15H Negative acknowledge
More obj. related items… Description