137
GB
MSL coded version
8 007 898/O369/05-04-04 Operating instruction • MSL cod. © SICK AG • Industrial Safety Systems • Germany • All rights reserved
Voltage in DC • Reference point for measured values: equipment plug
min. typ. max.
General system data
Operating range (depending on type)
Sender/Receiver 0,5 m 70 m
MSLZ 01-250 with PSK 45 0 m 7,5 m
MSLZ 01-250 with PSZ 01-1501 0 m 6,1 m
MSLZ 01-240 with PSK 45 0 m 4,5 m
MSLZ 01-240 with PSZ 01-1401 0 m 4,5 m
MSLZ 02-203 with PSK 45 0 m 4,5 m
MSLZ 02-203 with PSZ 01-1401 0 m 4,5 m
MSLZ 02-203 with PSZ 02-1011 S 01 0 m 4,5 m
Beam gap 50 mm 500 mm
Resolution (type-dependent) 73 mm
Protection class 1
Enclosure rating IP 65
Supply voltage U
V
19.2 V 24 V 28.8 V
Ripple
1
) 2.5 V
SS
Voltage if power fails (20 ms) 18 V
Synchronization optical, without separate
synchronization cable
On-transition time
After applying the supply voltage
of receiver and sender 0.8 s
Sender Unit
Test output U
V
– 1.4 V
Test input
Input resistance (HIGH) 2.4 kW (in relation to 0 V)
Sender, active 0 V 5 V
Sender, active 17.8 V U
V
Reaction time on test 90 ms 100 ms
NC contact opening time 100 ms
Wave length 880 nm
Power consumption
MSLS 7 W
MSLZ 12 W
Weight (for MSLS 03-140) 3.14 kg
6 Technical Data
241967_MSLcv_GB_3.p65 10.12.04, 09:40137
Schwarz