MSL coded version
8 007 898/O369/05-04-04 Operating instruction • MSL cod. © SICK AG • Industrial Safety Systems • Germany • All rights reserved
1
) The voltage must not exceed or fall below the limit values.
2
) Applies for voltages between U
V
and 0 V.
3
) In the case of an error (interruption of the 0 V cable) the outputs behaves like a resistor
> 13 kW after U
V
. The downstream control element must identify this state as LOW.
4
) With a low switching frequency (
1
/s) the max. permissible load inductance L is higher.
5
) In the active state, the outputs are tested in a cycle (switch LOW briefly). When selecting the
downstream control elements ensure that the test impulses with the parameters listed above
do not lead to a shutdown.
6
) The individual conductor resistor to the downstream control element must be limited to
this value so that a crossed connection between the outputs can be identified.
(EN 60 204
Electrical Equip. of Machines, Part 1: General Requirements
must be observed.)
1
1
2
2
I
L
400 mA
I
L
500 mA
L (H)
1/s
1,0 2,0 3,0 4,00
20
10
0
min. typ. max.
Operating data
Operating mode (type-dependent) with restart inhibit and external contact
monitoring
Safety category Type 4
Tested to pr EN 50 100 Part 1 and 2
Ambient operating temperature 0 °C +55 °C
Storage temperature –25 °C +70 °C
Air humidty (non-condensing) 15 % 95 %
Vibration resistance 5 g, 10 ... 55 Hz to IEC 68-2-6
Shock resistance 10 g, 16 ms to IEC 68-2-29
Dimensions see
dimensional drawings/fig. 3
241967_MSLcv_GB_3.p65 10.12.04, 09:40139