nanoScan3 Pro – EtherNet/IP™
Standards
IE
C 60068-2-6
IEC 60068-2-64
IEC 60721-3-5
IECTR 60721-4-5
IEC61496-3
Class
5M1 (IEC60721-3-5)
Sinusoidal vibrations
0.35mm, 50m/s², 10Hz … 150Hz
1.5mm, 1Hz … 9Hz
50m/s², 9Hz … 200Hz
10m/s², 10Hz … 1,000Hz
Noise vibrations
0.3m²/s³, 10Hz … 200Hz
0.1m²/s³, 200Hz … 500Hz
50m/s², 10Hz … 500Hz
Shock resistance
4)
Standards
IE
C 60068-2-27
IEC 60721-3-5
IECTR 60721-4-5
IEC61496-3
Class
5M1 (IEC60721-3-5)
Single shock 150m/s², 11ms
Continuous shock
50m/s², 11ms
100m/s², 16ms
EMC In accordance with IEC61496-1, IEC61000-6-2, and
IE
C61000-6-3
1)
The specified enclosure rating only applies if the optics cover and the system plug are mounted and the
U
SB connection is closed with the protective cover.
2)
For ambient light sources directly in the scan plane in accordance with IEC61496-3: ≤3klx
3)
IEC61496-1, no. 4.3.1and no. 5.4.2, IEC61496-3, no. 4.3.1 and no. 5.4.2. Condensation has an
influence on normal operation.
4)
For direct mounting.
Table 37: Miscellaneous data
nanoScan3 Pro – EtherNet/IP™
Type of light Pulsed laser diode
Wavelength 905nm
Detectable remission 1.8% … several 1,000%
Maximum uniform contami‐
nation of the optics cover
without reducing the detec‐
tion capability
1)
30%
Area where detection capabil‐
it
y is restricted
≤50mm
2)
Light spot size
3)
At front screen 9mm × 3mm
At 3.0m distance 15mm × 2mm
Pulse duration Typ. 4ns
Average output power 12.8mW
Laser class 1
4)
13 TECHNICAL DATA
120
O P E R A T I N G I N S T R U C T I O N S | nanoScan3 – EtherNet/IP™ 8027909/2023-02-22 | SICK
Subject to change without notice

Table of Contents