Scanning range of the reference contour field
T
he effective scanning range of the reference contour field is the same as the protec‐
tive field range.
Scanning range of the contour detection field
T
he effective scanning range of the contour detection field is the same as the protective
field range.
Warning field range and distance measurement range
F
or non-safety applications (warning fields, measurement data output), the safety laser
scanner has a larger scanning range than the maximum protective field range. The
requirements for size and remission factor of objects to be detected are illustrated
in the following graphs as a function of the desired scanning range. Under good condi‐
tions, in many cases a smaller object size or a lower remission factor is sufficient to
achieve the desired scanning range.
The range is limited to 10m for warning fields.
5 10 20 50 D [m]
d [mm]
1000
500
200
100
50
20
10
Figure 50: Range and object size for measured data output
d Required minimum size of the object in mm
D Scanning range in m
13 TECHNICAL DATA
122
O P E R A T I N G I N S T R U C T I O N S | nanoScan3 – EtherNet/IP™ 8027909/2023-02-22 | SICK