4.3.7.1 Protective field
In hazardous area protection, the minimum distance typically defines the protective
f
ield size required.
If you define a number of monitoring cases with different protective fields, you must
calculate the protective field size separately for each protective field used.
In many cases, a resolution of 50mm to 70mm is suitable for hazardous area
protection. Resolutions coarser than 70mm are not permitted.
4.3.7.2 Supplement C
R
O
to protect against reaching over
Overview
U
nder certain circumstances, a person can reach the hazardous area by reaching over,
before the protective device stops the dangerous state. The supplement C
RO
prevents
this.
D
H 0 mm
C
RO
= 1200 mm
Figure 15: Protection against reaching over with low scan plane (dimensions in mm)
PROJECT PLANNING 4
8027909/2023-02-22 | SICK O P E R A T I N G I N S T R U C T I O N S | nanoScan3 – EtherNet/IP™
27
Subject to change without notice