Technical specifications
8.4 Electromagnetic compatibility
SIMATIC IPC647E
Operating Instructions, 11/2018, A5E45589180-AA
147
8.4 Electromagnetic compatibility
See the note in "Applicability of technical specifications (Page 141)".
Interference emission EN 61000-6-3; EN 61000-6-4
CAN/CSA CISPR22 Class B, EN 55032 Class B; FCC Class A; KN 32 Class B
EN 61000-3-2 class D, EN 61000-3-3
Interference immunity
EN 61000-6-1; EN 61000-6-2; KN 35
Noise immunity:
interference conducted on the
power supply lines
± 2 kV; according to IEC 61000-4-4; burst
± 1 kV; according to IEC 61000-4-5; surge symm
± 2 kV; according to IEC 61000-4-5; surge symm
Noise immunity on signal lines ± 2 kV; per IEC 61000-4-4; burst; length < 3 m
± 1 kV; per IEC 61000-4-4; burst; length < 3 m
± 2 kV; according to IEC 61000-4-5; burst; length > 30 m
Immunity to discharges of static
electricity
± 6 kV contact discharge (according to IEC 61000-4-2)
± 8 kV air discharge; (according to IEC 61000-4-2)
Immunity to RF interference
10 V/m; 80 up to 2700 MHz
80% AM to IEC 61000-4-3
3 V/m; 2.7 to 6 GHz
80% AM to IEC 61000-4-3
10 V; 10 kHz up to 80 MHz
80% AM to IEC 61000-4-6
Magnetic field
100 A/m; 50 Hz; 60 Hz (according to IEC 61000-4-8)
See also
Permissible expansion for temperature range 0 to 50 °C (Page 103)