EasyManuals Logo

Siemens SIMATIC IPC647E User Manual

Siemens SIMATIC IPC647E
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #147 background imageLoading...
Page #147 background image
Technical specifications
8.4 Electromagnetic compatibility
SIMATIC IPC647E
Operating Instructions, 11/2018, A5E45589180-AA
147
8.4 Electromagnetic compatibility
See the note in "Applicability of technical specifications (Page 141)".
Interference emission EN 61000-6-3; EN 61000-6-4
CAN/CSA CISPR22 Class B, EN 55032 Class B; FCC Class A; KN 32 Class B
EN 61000-3-2 class D, EN 61000-3-3
Interference immunity
EN 61000-6-1; EN 61000-6-2; KN 35
Noise immunity:
interference conducted on the
power supply lines
± 2 kV; according to IEC 61000-4-4; burst
± 1 kV; according to IEC 61000-4-5; surge symm
± 2 kV; according to IEC 61000-4-5; surge symm
Noise immunity on signal lines ± 2 kV; per IEC 61000-4-4; burst; length < 3 m
± 1 kV; per IEC 61000-4-4; burst; length < 3 m
± 2 kV; according to IEC 61000-4-5; burst; length > 30 m
Immunity to discharges of static
electricity
± 6 kV contact discharge (according to IEC 61000-4-2)
± 8 kV air discharge; (according to IEC 61000-4-2)
Immunity to RF interference
10 V/m; 80 up to 2700 MHz
80% AM to IEC 61000-4-3
3 V/m; 2.7 to 6 GHz
80% AM to IEC 61000-4-3
10 V; 10 kHz up to 80 MHz
80% AM to IEC 61000-4-6
Magnetic field
100 A/m; 50 Hz; 60 Hz (according to IEC 61000-4-8)
See also
Permissible expansion for temperature range 0 to 50 °C (Page 103)

Table of Contents

Other manuals for Siemens SIMATIC IPC647E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC IPC647E and is the answer not in the manual?

Siemens SIMATIC IPC647E Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC IPC647E
CategoryIndustrial PC
LanguageEnglish

Related product manuals