Expanding and assigning parameters to the device
6.6 Drives
SIMATIC IPC647E
106 Operating Instructions, 11/2018, A5E45589180-AA
6.6.1.5 Changing a backplane for removable tray
The backplane is installed from inside at the back end of the drive cage type A and is
equipped with interfaces for data cable to the motherboard.
This enables the convenient connection of the data cables from the motherboard to the drive
in the removable tray at these interfaces.
Requirement
The device is equipped with the Type A drive cage, see Type A drive cages see "Drives
in drive cage type A (Page 101)" and for Type B drive cages see "Drives in drive cage
type B (Page 110)".
An original spare part, that is a backplane approved for this device, see notes in
"Hardware accessories (Page 29)".
The device is fully disconnected from the line voltage, see "Switching off the device
(Page 58)".
The device is open, see important information in "Open the device (Page 85)".
The drives have been removed, see "Change 2.5" and 3.5" drive in removable tray
(Page 104)".

Table of Contents

Other manuals for Siemens SIMATIC IPC647E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC IPC647E and is the answer not in the manual?

Siemens SIMATIC IPC647E Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC IPC647E
CategoryIndustrial PC
LanguageEnglish

Related product manuals