12 Functional Descriptions 04.96
12.25 Flexible memory configuration (SW 4 and higher)
12.25 Flexible memory configuration (SW 4 and higher)
12.25.1 Corresponding data
Machine data
• NC MD 60000 Size of UMS memory
• NC MD 60001 Size of part program memory
• NC MD 60002 Number of IKA points
• NC MD 60003 Memory for drive software for MSD
• NC MD 60004 Memory for drive software for FDD
• NC MD 60005 Number of tools
• NC MD 60006 Number of TO parameters per tool
• NC MD 60007 Number of channel-specific R parameters
• NC MD 60008 Number of central R parameters
• NC MD 60009 Unassigned residual memory, D-RAM
• NC MD 60010 Unassigned residual memory, S-RAM
• NC MD 60011 NC module memory configuration
• NC MD 6100* Number of block buffers in block memory in channels 1 to 6
• NC MD 6200* Number of axis-specific measured values for the "Extended measurement"
function
• NC MD 60013 Memory for real axes (as from SW 5)
• NC MD 61020 Memory for ”Extended overstore” (as from SW 5)
to 61025
General
The "Flexible memory configuration" function allows the user to influence the memory page
allocation for:
• User data
– Part program data
– UMS data
– IKA data
– R parameters
– TO data
– Data for real axes
– Data for extended overstore
• Drive software
In the case of analog drive systems, the memory space reserved for digital drive software
can be used to store user data.
• Number of axis-specific measured values:
For the "Extended measurement" function.
• Number of block buffers in block memory:
Depending on the capacity utilization of individual channels, it is possible to define on a
channel-specific basis the maximum permissible number of part program blocks which may
be pre-decoded during processing.
12–258
© Siemens AG 1992 All Rights Reserved 6FC5197- AA50