EasyManuals Logo

Siemens SINUMERIK 840C Installation Instructions

Siemens SINUMERIK 840C
1154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #894 background imageLoading...
Page #894 background image
10.94 12 Functional Descriptions
12.16.3 Installation
12.16.3 Installation
The compensation value of the QEC essentially depends on the machine configuration.
The easiest way to install QEC is to carry out a circularity test. With a circularity test,
deviations from the programmed radius when a circle is described can be measured and
displayed graphically, most especially at the quadrant transition points. To obtain an optimum
compensation in the whole working range of the QEC, the compensation dependancy on the
acceleration must also be considered. This is done by measuring this dependancy at various
points in the range between acceleration 0 and set maximum acceleration. The characteristic
obtained from these measurement results must then parameterized axis-specifically in machine
data 1232*, 1236*, 1240*, 1248*, and 1252*
See Section 5, MDD, Section File functions, for a description of how to save NQEC data.
_______
1) 100 % in the two compensation values from MD 1232* and 1240* correspond to a speed setpoint of 1V in
analog drives and to 10 % of the maximum speed set in the drive system in digital drives.
© Siemens AG 1992 All Rights Reserved 6FC5197- AA50 12–119
SINUMERIK 840C (IA)

Table of Contents

Other manuals for Siemens SINUMERIK 840C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840C and is the answer not in the manual?

Siemens SINUMERIK 840C Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 840C
CategoryControl Unit
LanguageEnglish

Related product manuals