EasyManuals Logo

Siemens SINUMERIK 840C Installation Instructions

Siemens SINUMERIK 840C
1154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1078 background imageLoading...
Page #1078 background image
10.94 12 Functional Descriptions
12.29.2 General hardware conditions for ”Extended measurement”
No check is made to ascertain whether R parameters which are also required by other
functions are being overwritten. Which R parameters within the available parameter range are
used is left to the discretion of the user.
If the programmed G720/G721 variant (probe selection, edge selection, etc.) is not supported
by the measuring circuit hardware, the axis-specific RESET alarm 1076* "Hardware
measurement" is output.
The following steps can be taken to avoid this problem:
When taking measurements with the second probe (MT = 2), program PCA and/or 611D
axes only.
In mixed operation 611D/PCA with SPC/HMS, program "first probe input" (MT = 1) and
"negative edge" (MF = 1) only.
Alarm 1076* is also output if the active measuring system is switched over when
measurements are in progress.
© Siemens AG 1992 All Rights Reserved 6FC5197- AA50
12–303
SINUMERIK 840C (IA)