During data transmission the following dialog text appears:
!!! Transmission of NC to PC active !!!
If a file of the same name already exists, you are asked if you want to overwrite
this file:
PC data exist. Overwrite ?
You acknowledge with the OK softkey.
Press the softkey LOAD to load the data selected into the NCK CPU. The pass-
word must have been entered in the NCK area.
The following dialog text appears during data transmission.
!!! Transmission from PC to NC active !!!
MACHINE PARAMETER PROGRAMM. SERVICES
14:45
Start-up/SIEMENS/NC data
Start-up/User/NC data
NC
Name
Length Date
NC/data
Name
Length Date
...
..
TEA1 96145 02–17–1993 13:21:22
SEA1 96145 02–18–1992 08:06:36
SEA1 10440 02–17–1993 13:21:44
ABORT
DIAGNOSIS
!!! Transmission from PC to NC active !!!
Fig. 4.25 SW 1
The Operator’s Guide describes how to edit NC data.
4 MMC Area Diagnosis
4.8.1 NC data management (up to SW 2)

Table of Contents

Other manuals for Siemens SINUMERIK 840C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840C and is the answer not in the manual?

Siemens SINUMERIK 840C Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 840C
CategoryControl Unit
LanguageEnglish

Related product manuals