09.95
ï›™
Siemens AG 2001 All Rights Reserved 6FC5197–jAA50
5–10
SINUMERIK 840C (IA)
Spindle
S Mode group:
The assignment of mode group to spindle is determined by the setting in NC
MD 4530 ff (spindle valid in mode group).
S Available:
The spindle is displayed as existing when NC MD 5210.7 ff (spindle exists) is
set.
Axis No.
S Mode group:
The assignment of mode group to axis no. is determined by the setting in NC
MD 3600 ff (axis no. valid in mode group).
S Name
The name of the axis appears in this window when NC MD 5680 ff (axis
name) is set.
Possible inputs are: X–X15, Y–Y15, Z–Z15, A–A15, B–B15, C–C15, U–U15,
V–V15, W–W15, Q–Q15, E–E15.
S Available:
The axis is displayed as existing when NC MD 5640.7 ff (axis exists) is set.
S Axis type:
The display tells you whether the axis is real or fictitious, as set in NC MD
5640.6 ff.
real: Input = No
fictitious: Input = Yes
S Rotary axis:
The display tells you whether the axis is a linear or rotary axis, as set in NC
MD 5640.5 ff.
linear: Input = No
rotary: Input = Yes
Notes Only the channels, axes and spindles defined in the NC configuration display are
also displayed in the following displays (channel, axis, spindle MD softkeys).
You must execute a PLC cold restart via the General reset mode function if you
wish to alter the number of channels, spindles and axes.
5 Machine Data Dialog (MDD – as from SW 3)
5.2.1 NC configuration