6 NC Machine Data (NC MD), NC Setting Data (NC SD) 09.95
6.3 Channel-specific MD (channel data)
Reset state G group
108*-122*
Default value Lower input limit Upper input limit Units
see below
see table of input
values
see table of input
values
–
Active in block
prior
to
decodg
The reset state for G groups 1, 3, 6, 8, 12, 15 and 25 may be defined on a channel-specific
basis.
Only those G functions shown in the table below may be specified in NC MD 108* to 122* for
the relevant G group.
The reset state for G group 9 (G70/G71) is defined together with the input resolution in
NC MD 5002.
Default value
T M G group
108* 1 1 1
110* 18 17 3
112* 54 54 6
114* 64 60 8
116* 0 0 9
118* 95 94 12
120* 150 150 15
122* 450 450
1)
25
Table of input values
Internal
G group
G functions
0
00
MD
01
M/T
MD
10
MD
11
MD
02
MD
03
MD
33
MD
34
MD
35
MD
06
MD
12
MD
13
MD
36
MD
1 09
2
17
M
MD
18
T
MD
19
MD
16
3
40
M/T
41 42
4 53
5
54
M/T
MD
55
MD
56
MD
57
MD
6 04 25 26 58 59 92 74
7
60
M
MD
63
MD
64
T
MD
62
MD
8 70 71
_______
1) As from SW 2
6–32 © Siemens AG 1992 All Rights Reserved 6FC5197- AA50
SINUMERIK 840C (IA)

Table of Contents

Other manuals for Siemens SINUMERIK 840C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840C and is the answer not in the manual?

Siemens SINUMERIK 840C Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 840C
CategoryControl Unit
LanguageEnglish

Related product manuals