09.95
Siemens AG 2001 All Rights Reserved 6FC5197jAA50
2-7
SINUMERIK 840C (IA)
Setting ranges
for SRAM
Default values Setting ranges
Tool offsets
32 kB
0 to 1 638 tools
0 to 64 kB
R parameters
19 kB
Channel:0 to 700 parameters
Central: 700 to 9 999 parameters
0 to 64 kB
Free
13 kB
64 kB are available for tool offsets and R parameters.
Caution:
The memory must be reformatted after every change.
SK “NCK AWS format. In general reset mode.
Changing the memory The operating sequence Changing the memory configuration (see below) must
configuration be performed if the size of any of the following memories changes:
S FDD/MSD for digital drives
S UMS memory
S PP memory
S IKA (see Sect. 12: Interpolation and compensation with tables and tempera-
ture compensation)
S Block buffer (see Sect. 12: FIFO/predecoding)
S Measured value memory (see Sect. 12: Extended measuring)
Inputs Procedure for changing the memory configuration
Step Operation
1 Select general reset mode in the operating area diagnostics.
2 Selection of the file function: SK machine data/SK NC-MD/key ETC/
SK memory config./SK file function
3 Copy the file NCMEMCFG from the Siemens branch to the user
branch with SK Preset
Caution! If the file NCMEMCFG is already in the user branch it is
overwritten with the default values.
4 Make the necessary settings in the file NCMEMCFG by editing the
user file.
5 Press SK Reconfig. memory”.
The settings are transferred to the NC-MD and the memory is reconfi-
gured.
6 Reconfigure NCK user memory if the setting has been changed for
the SRAM. SK Format NCK AWS. Press initial clear in the display.
7 Deselect general reset mode
8 The values set can be checked in NC-MD 60000 to 62029.
9 Save the file NCMEMCFG from directory NC/data with PC format.
2 General Reset and Standard Start-Up
2.5 Memory configuration (as from SW 3)

Table of Contents

Other manuals for Siemens SINUMERIK 840C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 840C and is the answer not in the manual?

Siemens SINUMERIK 840C Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 840C
CategoryControl Unit
LanguageEnglish

Related product manuals