7 Drive Machine Data (SIMODRIVE Drive MD) 10.94
7.1.2 MSD MD (data description - SW 3)
Programmable message 2
242
Default value Lower input limit Upper input limit Units
3 1 20
Active
at once
A function can be assigned to programmable message 2 in this machine data.
The default setting corresponds to M
d
> M
dx
(see MD 241 for other settings).
Programmable message 3
243
Default value Lower input limit Upper input limit Units
1 1 20
Active
at once
A function can be assigned to programmable message 3 in this machine data.
The default setting corresponds to n
act
< n
min
(see MD 241 for other settings).
Programmable message 4
244
Default value Lower input limit Upper input limit Units
4 1 20
Active
at once
A function can be assigned to programmable message 4 in this machine data.
The default setting corresponds to n
act
< n
x
(see MD 241 for other settings).
Programmable message 5
245
Default value Lower input limit Upper input limit Units
20 1 20
Active
at once
A function can be assigned to programmable message 5 in this machine data.
The default setting corresponds to variable relay function 1 (MD 185, see MD 241 for other
settings).
Programmable message 6
246
Default value Lower input limit Upper input limit Units
7 1 20
Active
at once
A function can be assigned to programmable message 6 in this machine data.
The default setting corresponds to variable relay function 2 (MD 190, see MD 241 for other
settings).