09.95
ï›™
Siemens AG 2001 All Rights Reserved 6FC5197–jAA50
4–20
SINUMERIK 840C (IA)
Parking axis setpoint This display field shows the status of parking axis of cyclic control word 1
(drive MD 11004.1)
Possible display range: off or on
Travel to fixed stop This display field contains the status of Travel to fixed stop of cyclic status word 2
actual (drive MD 11003.13)
Possible display range: off or on
Speed setpoint This display field contains the status of speed setpoint smoothing of cyclic status
smoothing actual value word 1 (drive MD 11002.11).
Ramp-function This display field contains the status of ramp-function generator rapid stop of
generator rapid cyclic status word 1 (drive MD 11002.9).
stop actual value Possible display range: off or on
V/F mode This display field contains the status of V/F mode of cyclic status word 2
(drive MD 11003.12).
Possible display range: off or on
2nd torque limit This display field shows the status of 2nd torque limit of cyclic status word 1
actual value (drive MD 11002.10).
Possible display range: off or on
Integrator inhibit This display field shows the status of the integrator inhibit of cyclic status word 1
actual value (drive MD 11003.6).
Possible display range: off or on
Motor temperature This display field shows the state of the motor temperature warning
warning (drive MD 11006.14)
Possible display range: off or on
Heat sink temperature This display field shows the state of the heat sink temperature warning
warning (drive MD 11006.15)
Possible display range: off or on
Ramp-up completed This display field shows the current status of the message Ramp-function
(SW 4) procedure completed (drive MD 11007.0).
IM
d
I < M
dx
(SW 4) This display field shows the current status of the message IM
d
I< M
dx
(drive MD
11007.1).
In
act
I < n
min
(SW 4) This display field shows the current status of the message In
act
I< n
min
(drive MD
11007.2).
In
act
I < n
x
(SW 4) This display field shows the current status of the message In
act
I< n
x
(drive MD
11007.3).
n
set
< n
act
(SW 4) This display field shows the current status of the message n
set
< n
act
(drive MD
11007.4).
Variable message This display field shows the current status of the message Variable message
function (SW 4) function (drive MD 11007.5).
4 MMC Area Diagnosis
4.3 Drive service displays for spindle (MSD) and axis (FDD) – as from SW 3)