Data and command errors Error code
[errorCode]
Add info
[errorAd‐
dInfo]
Description
9500 Fault present
9501 No stability
9502 Waiting for stability
9511 Write protection enabled
9532 Current weight is out of defined weighing range
9533 Total too small
9550 Trace memory full
9551 Protocol memory full
9552 Logging task is busy
9553 Weight did not change since last logging
9554 Logbook contains no entries
7050 Unknown data record 7050 - Requested data record is unknown.
7051 Parameter input not
possible now
7051 A parameter input is currently not possible. Additional information
contains details.
9507 Dosing active
9510 Service mode is not active
9511 Write protection enabled
7052 Parameter is write pro‐
tected and cannot be
changed
7052 A parameter input is currently not possible due to active write pro‐
tection. Additional information contains details about the parameter
involved.
Parame‐
ter ID
Parameter ID of the parameter involved
7053 Error in calibration pa‐
rameter DR03
7053 Additional information indicates an implausible parameter in DR 3
Parame‐
ter ID
Parameter ID of the affected parameter in DR 3
9510 Service mode is not active
9520 Increment between calibration digits too small
9521 Sequence of calibration points is not correct
9524 Calibration weight is 0
9525 Falling characteristic curve not allowed by OIML
9526 Alternating calibration characteristic curve is not allowed
9610 Weighing range max - min error
9611 Resolution not permitted
9613 OIML and 6000d provision violated
9614 Zeroing or zero setting limits are not OIML-compliant
7054 Parameter error DR05 7054 Additional information indicates an implausible parameter in DR05
Parame‐
ter ID
Parameter ID of the affected parameter in DR05
Interrupts/diagnostic messages
9.4 Operating errors
Technology module TM SIWAREX WP351 HF
Operating Instructions, 01/2020, A5E47521010-AA 135