EasyManua.ls Logo

Sony DVS-9000SF - Page 256

Sony DVS-9000SF
462 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 16 Engineering Setup
256
Setup Relating to Operations From the Control Panel
Setting VTR operation button assignment
You can change the assignment of some of the buttons in a standard type
transition control block for use in VTR operations. Use the following
procedure.
1
In the Panel>Config menu, press [Program Button].
The Program Button menu appears.
2
Press [Transition Module].
The Transition Module menu appears.
3
Using any of the following methods, select the bank.
Press directly on the list in the status area.
Press the arrow keys to scroll the reverse video cursor.
Turn the knob.
4
Select the assignment for the [PTN LIMIT], [LIMIT SET], and [KF]
buttons in the standard type transition control block from the <PTN
LIMIT/LIMIT SET/KF Button Assign> group.
Ptn Limit /KF: These are used as the [PTN LIMIT] button, [LIMIT SET]
button, and [KF] button.
Play/Stop/Cue: These are used as the [PLAY] button, [STOP] button, and
[CUE] button for VTR operation.
Inhibit: Inhibit operations with these buttons.
5
Select the assignment for the [NORM], [NORM/REV], and [REV] buttons
in the standard type transition control block from the <NORM/NORM
REV/REV Button Assign> group.
Normal/Reverse: These are used as the [NORM] button, [NORM/REV]
button and [REV] button.
Play/Stop/Cue: These are used as the [PLAY] button, [STOP] button, and
[CUE] button for VTR operation.
Inhibit: Inhibit operations with these buttons.
Setting the assignment of macro operation buttons
Note
This setting is disabled for the CCP-9000.
Knob Parameter Adjustment Setting values
1 Bank Bank selection 1 to 4

Table of Contents