Chapter 16 Engineering Setup
304
Setup Relating to Switcher Processor
Setting the default wipe edge softness
Use the following procedure.
In the Switcher>Key/Wipe/FM menu, adjust the following parameter to set the
default value.
Settings Relating to Function Links (Link Menu)
Carry out setup relating to links by displaying the Switcher>Link menu.
To display the Link menu
In the Engineering Setup menu, select VF3 ‘Switcher’ and HF6 ‘Link.’
The status area shows the current link information.
Setting a cross-point button link
To link together two buses internal to the switcher, use the following
procedure.
1
In the Switcher>Link menu, press [Internal Bus Link].
The Internal Bus Link menu appears.
The status area shows the link source and link destination buses, and link
table information.
2
Using any of the following methods, select what setting applies to.
• Press directly on the list appearing in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob.
3
Press [Link Bus Select].
The Link Bus Select menu appears.
The status area lists the current setting status of the selected link and the
buses that can be selected.
Knob Parameter Adjustment Setting values
3 Wipe Edge
Soft
Default value of wipe edge softness
–50.00 to +50.00
Knob Parameter Adjustment Setting values
1 Link No Link number 1 to 64