317Setup Relating to DME
Chapter 16 Engineering Setup
Setup Relating to DME
Settings Relating to Signal Inputs (Input Menu)
To make settings relating to DME input signals, display the DME>Input menu.
To display the Input menu
In the Engineering Setup menu, select VF4 ‘DME’ and HF1 ‘Input.’
The status area shows the initial crop information and the MVE-9000 system
phase.
In the following, the settings for DME1 are explained. (It is not necessary to
make settings for DME2.)
Setting the initial crop
Use the following procedure.
1
In the DME1 <Aspect> group, select the screen aspect ratio (16:9 or 4:3).
2
In the DME1 <Crop> group, press [Initial Crop] and adjust the following
parameters.
If you selected 4:3 in step 1
If you selected 16:9 in step 1
To return the parameter values to their default values
Knob Parameter Adjustment Setting values
1 Top Position of top side –3.00 to +3.00
2 Left Position of left side –4.00 to +4.00
3 Right Position of right side –4.00 to +4.00
4 Bottom Position of bottom side –3.00 to +3.00
Knob Parameter Adjustment Setting values
1 Top Position of top side –9.00 to +9.00
2 Left Position of left side –16.00 to
+16.00
3 Right Position of right side –16.00 to
+16.00
4 Bottom Position of bottom side –9.00 to +9.00