329Setup Relating to DCU
Chapter 16 Engineering Setup
4
In the <Parallel Output Assign> group, press [No Assign].
GPI Output Setting (GPI Output Assign Menu)
To set the trigger type and so on for each GPI output, display the DCU>GPI
Output Assign menu.
To display the GPI Output Assign menu
In Engineering Setup, select VF5 ‘DCU’ and HF4 ‘GPI Output Assign.’
The GPI output port setting status appears in the status area.
Making DCU GPI output settings
Use the following procedure.
1
In the DCU>GPI Output Assign menu, using any of the following methods
select what the setting applies to.
Press directly on the list appearing in the status area.
Press the arrow keys to scroll the reverse video cursor.
Turn the knob.
2
In the <Trigger Type> group, select the trigger polarity.
(Rising Edge): The trigger causes the relay contacts to be open-
circuit or drives the output high, and holds this state for the
specified pulse width.
(Falling Edge): The trigger causes the relay contacts to be shorted
or drives the output low, and holds this state for the specified
pulse width.
: Each time the trigger occurs, the relay contacts are alternately
closed or opened, or the output is switched between high and
low.
Status: Depending on the status, the relay contacts are closed or opened,
or the output is switched between high and low.
No Operation: The trigger has no effect on the relay state or output level.
4 To Port Last port number 1 to 54
Knob Parameter Adjustment Setting values
Knob Parameter Adjustment Setting values
1 No GPI output 1 to 50

Table of Contents