Chapter 16 Engineering Setup
348
Setup Relating to Router Interface and Tally
6
When setting the tally type, set the following parameters.
a) When you selected Group1 to 4 in the section “Setting the tally groups” (page 341), this is
1:R1, 2:G1, 3:R2, 4:G2, 5:R3, 6:G3, 7:R4, and 8:G4.
When you selected Group5 to 8, this is 1:R5, 2:G5, 3:R6, 4:G6, 5:R7, 6:G7, 7:R8, and
8:G8. (R is an abbreviation of “Red Tally,” and G of “Green Tally.”)
7
Press [Execute].
This makes the parallel tally settings, in accordance with the settings in
steps 1 to 6.
Deleting parallel tally settings
Use the following procedure.
1
In the Router/Tally>Parallel Tally menu, using any of the following
methods, select the parallel tally whose settings you want to delete.
• Press directly on the list appearing in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knobs.
2
Press [Clear].
This deletes the selected parallel tally entry.
Serial Tally Settings (Serial Tally Menu)
To make serial tally settings, display the Router/Tally>Serial Tally menu.
Knob Parameter Adjustment Setting values
1 Address Destination address 1 to 1024
2 Level Destination level 1 to 8
Knob Parameter Adjustment Setting values
3 Type Tally type
1 to 8
a)
Knob Parameter Adjustment Setting values
1 Slot No Parallel tally slot number 2 to 6
2 Port No Parallel tally port number 1 to 54