Chapter 16 Engineering Setup
318
Setup Relating to DME
Press [Unity] in the <Crop> group.
Setting an illegal color limit for matte signals
To enable the illegal color limiter for the signals generated by the DME internal
matte generator, press [Matte Illeg Col Limit] for DME1 in the DME>Input
menu, turning it on.
Making MVE-9000 system phase adjustment
To adjust the MVE-9000 reference phase, use the following procedure.
1
Press [System Phase].
2
Set the following parameters.
Setting the monitor output
To set the signals output from the four MVE-9000 monitor output connectors,
use the following procedure.
1
In the Engineering Setup menu, select VF4 ‘DME’ and HF3 ‘Output.’
The Output menu appears.
2
Press [Monitor Output].
The Monitor Output menu appears.
3
In the <Select> group, select the DME to which the setting applies.
DME1: Select DME1.
DME2: Select DME2.
4
In the list on the left of the status area, press directly on the monitor output
for which you want to make setting.
5
In the list on the right of the status area, press directly on the signal you
want to output.
6
Press [Set].
Knob Parameter Adjustment Setting values
1DME1
Phase
DME1 system phase adjustment –32.00 to +96.00
2DME2
Phase
DME2 system phase adjustment –32.00 to +96.00