261Setup Relating to Operations From the Control Panel
Chapter 16 Engineering Setup
Setting the action of the [SHIFT] button in the cross-point control
block
In the <Shift Mode> group of the Panel>Xpt Assign>Multi Xpt Assign menu,
select either of the following.
Display: Functions as a shift button dedicated to the source name displays.
Shift All Bus: Functions as a shift button for all buses.
Notes
• It is not possible to make this setting separately for individual switcher
banks.
• “Shift All Bus” is only valid when the cross-point button shift operation (see
previous item) is set to “Lock” or “Off.”
Exporting source names and destination names
To send the source names and destination names to the S-Bus, use the
following procedure.
1
In the Panel>XPT Assign menu, press [Name Export].
The Name Export menu appears.
2
Turn the knob to set the station ID.
a) If set to 255, the information is sent to all stations.
3
Press [Src Name Export].
This exports the source names to the station selected in step 2.
4
Press [Dest Name Export].
This exports the destination names to the station selected in step 2.
Note
Since destination names cannot be selected freely, fixed names are used.
Knob Parameter Adjustment Setting values
1 Station ID Station ID setting
1 to 255
a)