Chapter 16 Engineering Setup
340
Setup Relating to Router Interface and Tally
1
In the External Box Assign menu, select [External box1] from the
<Device> group.
2
In the <Matrix Size> group, select [8×1].
3
Turn the knobs to make adjustments.
4
In the <Device> group, select [External box2].
5
In the <Matrix Size> group, select [32×1].
6
Turn the knobs to make adjustments.
At this point make the settings of Destination and Level the same as in step
3.
This automatically couples External Box1 and External Box2, forming an
external box with 40 (8+32) inputs.
To set the group number of an S-Bus description name
Use the following procedure.
1
In the <Alias Name Gp> group of the Router/Tally>Router menu, press
[Gp No].
2
Turn the knob to set the following parameter.
a) When setting values 1 to 7 are selected: If the name is not set, the description name for 0
appears. If the description name for 0 is not registered either, the Type and No values
appear.
3
In the <Alias Name Gp> group, press [Set].
This confirms the setting, which is reflected in the status area.
Note
Transmit the description name selected here from the router.
Knob Parameter Adjustment Setting values
1 Source Source start address 1 to 1017
2 Destination Destination start address 1 to 1024
3 Level Level 1 to 8
Knob Parameter Adjustment Setting values
1 Gp No Group number of S-Bus
description name
0 to 7
a)